thru 2 0 a m p features high surge capacity low forward voltage drop high current capability, high efficiency marking : type number mcc catalog number maximum recurrent peak reverse voltage maximum rms voltage maximum dc blocking voltage mbr2020 f ct 20v 14v 20v mbr2030 f ct 30v 21v 30v mbr2035 f ct 35v 24.5v 35v mbr2040 f ct 40v 28v 40v mbr2045 f ct 45v 31.5v 45v electrical characteristics @ 2 5 c unless otherwise specified average forward current i f(av) 20 a t a = 120 c peak forward surge current i fsm 150a 8.3ms, half sine maximum instantaneous forward voltage 2020 f ct-2045 f ct 2060 f ct v f .70v .80v 2020 f ct-2045 f ct 2060 f ct .84v .95v 2080 f ct-20100 f ct .95v i fm = 20a; t a = 25 c i fm = 10a; t a = 25 c 2080 f ct-20100 f ct .85v 2020 f ct-2045 f ct 2060 f ct .72v .85v 2080 f ct-20100 f ct .85v i fm = 20a; t a =1 25 c mbr 20 100 f ct 100 v 70v 100v mbr 20 80 f ct 80v 56v 80v mbr 20 60 f ct 60v 42v 60v i r 2 0 to 100 volts maximum ratings operating temperature: -5 5 c to +150 c storage temperature: -5 5 c to +150 c maximum dc reverse current at rated dc blocking voltage 2020 f ct~2045 f ct 2060 f ct~20100 f ct 2020 f ct~2045 f ct 2060 f ct~20100 f ct t a = 25 c t a = 1 25 c 0.1ma 0.15ma 50ma 150ma barrier rectifier schottky mbr2020 f ct mbr20100 f ct omp onents 20736 marilla street chatsworth ! " # $ % ! " # i to-220ab pin 1 pin 3 pin 2 a b c k j i h g e d n m l h pin 13 2 inches mm
a . 583 .6 06 14. 80 15. 40 b --- . 4 0 6 --- 10.30 n .0 98 .11 4 2. 50 2.9 0 o f c .100 .1 12 2.5 5 2.85 d .2 48 .27 2 6 . 30 6. 90 e --- . 1 6 1 - - - 4.10 f --- . 0 7 1 --- 1.80 g . 512 .5 43 13.00 13.80 h .100 2.55 i --- . 035 --- 0.90 j --- . 032 --- 0.80 k .1 18 .1 34 3.00 3.40 l --- . 189 --- 4.8 0 m --- . 130 --- 3.30 o --- . 055 --- 1.40 x case material: molded plastic. ul flammability classification rating 94v-0 www.kersemi.com
mbr2020 f ct thru mbr20100 f ct average forward rectified current - amperes versus ambient temperature - c figure 3 forward derating curve 25 50 100 125 150 0 0 10 12 14 single phase, half wave 60hz resistive or inductive load amps c 75 16 18 20 instantaneous forward current - amperes versus instantaneous forward voltage - volts figure 1 typical forward characteristics volts 4 6 20 10 amps . 2 .7 .3 .4 .5 .6 .01 .02 .04 .06 .1 .2 .4 .6 1 2 25 c 40 60 100 .8 1 100 4 0 25 50 75 8 figure 4 peak forward surge current peak forward surge current - amperes versus number of cycles at 60hz - cycles amps cycles 2 6 10 20 60 80 40 100 125 150 2080 f ct-20100 f ct 2020 f ct-2045 f ct 2060 f ct figure 2 typical reverse characteristics 0 20406080100120140 0.001 0.01 0.1 1 10 50 volt s [%] ma t = 25 c o a t = 75 c o a t = 125 c o a m b r 2 0 20 f c t - m br 2 0 4 5 f c t m b r 2 0 6 0 f c t - m br 2 0 10 0 f c t m br 2 0 6 0 f c t - m br 2 0 10 0 f c t m b r 2 0 20 f c t - m br 2 0 4 5 f c t instantaneous reverse leakage current - m ampere percent of rated peak reverse voltage - volts % www.kersemi.com
|